Negative Pressure Unit D 910 Negative Pressure Unit D 910


Method of use:

The negative pressure D 910 product line has been designed to filtrate and exhaust controlled amounts of room air to create negative pressure isolation rooms. This is done by the 3-stage HEPA filtration system. The device has been specially designed to operate in asbestos removal areas.
Over pressure technology to prevent penetration of contaminated ambient air into the housing.

Functional principle:

Functional principle

=> Due to over pressure technology it is suitable for operation in the asbestos removal area

More highlights:
- rust-proof housing, powder coated material
- smooth housing and easy-to-decontaminate
- operator control and function elements are shock protected, fixed castor- and steering rollers Ø125
- threefold sealed HEPA filter
- low emission during filter replacement in 3 minutes
- variable capacity control 0 - 100%
- automatic soft start

Technical data:
- dimensions (LxWxH): 1160 x 725 x 1140 mm
- weight incl. filter: 116 kg
- air capacity with filter: 6000 m³/h
- elec. connection: 230 Volt, 50 Hz
- operating current: 16 Ampere
- motor power: 3 kW
- hose connection: ND 450 (exhaust air)
- filter system 3-step
- pre-filter EU 3: 610 x 910 x 47 mm
- intermediate filter EU 4: 610 x 910 x 47 mm
- HEPA filter acc. to EN 1822 class H13: 610 x 910 x 292 mm

pre-filter 610 x 910 x 47
pre-filter
610 x 910 x 47 mm
Art.-No. BO2079

intermediate filter 610 x 910 x 47
intermediate filter
610 x 910 x 47 mm
Art.-No. BO2080

HEPA filter 610 x 910
HEPA filter
610 x 910 x 292 mm
Art.-No. AU1044


Options:
- automatic negative pressure control SRE
- audio-visual indicator for filter replacement
- free colour choice according to RAL-card
- add-on housing for pocket filter, activated carbon filter or additional HEPA filter
- hose connection flange at inlet side 2x ND 450