D 130 L
 
 
Planned use:
 
During asbestos removal within closed rooms, you have to exclude that asbestos fibres fly out of the sanitation area without control and represent a danger for human beings and environment. That is the reason why persons who leave the sanitation area via locks go under the shower by the outward transport. The deconta water treatment management cares for the heating of the shower water and assume the filtration of the contaminated waste water
Inside the powder coated device is the water tank (Volume 130 Litres),with an immersion heater, 2 pumps (shower and sewage water pump) as well as a 3 stages waste water filtration unit are installed within the device The filling-in depending on the temperature (step by step), water temperature selected freely up to + 80° C.
A preliminary filter 220µ, a fine filter 50µ and a fine filter 1µ belong to the filtration unit.
 
 
Technical Data:
 
bullet
Power connection: Schuko plug 230 V / 50 Hz
bullet
Power input 16 A
bullet
Fuse: FI-switch 30 mA
bullet
Radiator power 3 KW
bullet
Flow rate shower water: about 12 ltr./min.
bullet
Hose connection: System Geka
bullet
Measurements (LxBxH): 725 x 700 x 1130 mm
bullet
Weight (with empty tank): 70,5 kg
 
 
               www.deconta.com