D 60

 

      

 

 

Method of use:

 

The negative pressure  D 60 product line has been designed to filtrate and exhaust controlled amounts of room air to create negative pressure isolation rooms.

This is done by the 2-stage HEPA filtration system.

The device has been specially designed to operate in asbestos removal areas.

 

Over pressure technology to prevent penetration of contaminated ambient air into the housing.

 

 

Functional principle:

 

bullet

Due to over pressure technology suitable for operation in the asbestos removal area

 

 

 

More highlights:

 

bulletrust-proof housing, powder coated material, thereby weatherproof and suitable for outdoor application
bulletsmooth  housing and easy-to-decontaminate
bulletoperator control and function elements are shock protected
bulletintegrated coiling device for cable
bulletthreefold sealed HEPA filter
bulletlow emission during filter replacement in 3 minutes
bulletvariable capacity control 0 - 100%
bulletautomatic soft start, also after power failure

 

 

Technical data:

 

bullet

dimensions (LxWxH) 560 x 400 x 400 mm

bullet

weight with filter 19,5 kg

bullet

air capacity with filters 600 m³/h

bullet

elec. connection 230 Volt, 50 Hz

bullet

operating current 1 Ampere

bullet

motor power 0,17 kW

bullet

hose connection ND 150 (exhaust air)

bullet

2-stage filter system

bullet

intermediate filter EU 4

bullet

HEPA filter acc. EN 1822 class H13

 

 

Options:

 

bullet

add-on housing for pocket filter, activated carbon filter or additional HEPA filter

bullet

audio-visual indicator for filter replacement

bullet

free colour choice according to RAL-card

bullet

hose connection flange at inlet side 4 x ND 100, separately adjustable

bullet

hose connection flange at inlet side ND 150

 

 

               www.deconta.com