Method of use:
The negative pressure D 305 product line has been designed to filtrate and exhaust controlled amounts of room air to create negative pressure isolation rooms.
This is done by the 3-stage HEPA filtration system. The device has been specially designed to operate in asbestos removal areas.
Over pressure technology to prevent penetration of contaminated ambient air into the housing.
Functional principle:
|
Due to over pressure technology suitable for operation in asbestos removal areas |

More highlights:
|
rust-proof housing, powder coated material, thereby weatherproof and suitable for outdoor application | |
|
smooth housing and easy-to-decontaminate | |
|
operator control and function elements are shock protected, fixed castor- and steering rollers Ø125 | |
|
threefold sealed HEPA filter | |
|
low emission during filter replacement in 3 minutes | |
|
variable capacity control 0 - 100% | |
|
automatic soft start, also after power failure |
Technical data:
|
dimensions (LxWxH) 930 x 420 x 840 mm | |
|
weight incl. filter 45 kg | |
|
air capacitiy with filter 2000 m³/h | |
|
elec. connection 230 Volt, 50 Hz | |
|
operating current 9 Ampere | |
|
motor power 1,5 kW | |
|
hose connection ND 300 (exhaust air) | |
|
3-stage filter system | |
|
pre-filter EU 3 | |
|
intermediate filter EU 4 | |
|
HEPA filter acc.to EN 1822 class H13 |
Options:
|
capacity control ON / OFF | |
|
automatic negative pressure control SRE | |
|
audio-visual indicator for filter replacement | |
|
free colour choice according to RAL-card | |
|
add-on housing for pocket filter, activated carbon filter or additional HEPA filter | |
|
hose connection flange at inlet side ND 300 |