Use:
Extractor in order to filter out the air contaminated with asbestos through a 3 stages filtering unit. Ventilator and filter in one device.
The devices qualified with CE correspond to the TRGS 519 (technical rules for dangerous substances in Germany) and produce evidence in their daily use all over Europe.
The inserted high efficiency submicron particulate airfilters correspond to the requirements to EN 1822 class H13.
Technical data:
|
|
|
Compact 900 |
Compact 1.800 |
|
Output data |
Air volume with filter |
900 m³/h |
1800 m³/h |
|
Connection |
230 V |
230 V |
|
|
Supply terminals |
16 A |
16 A |
|
|
Engine output |
0,55 kW |
1,5 kW |
|
Measurements |
Length, Breadth, Height |
810 x 450 x 430 mm |
920 x 490 x 780 mm |
|
Weight |
about 30 kg |
about 70 kg |
|
|
Hose connection NW |
150 mm |
300 mm |
|
|
Filter data |
Absolute filter |
305 x 305 x 292 mm |
610 x 305 x 292 mm |
|
Preliminary filter EU 3 |
305 x 305 x 047 mm |
610 x 305 x 047 mm |
|
|
Intermediate filter EU 4 |
305 x 305 x 047 mm |
610 x 305 x 047 mm |
|
Option |
|
4-fold adapter |
5-fold adapter |
Model:
3 different possibilities of command can be delivered:
|
On / Off | |
|
SE Output regulation | |
|
SRE automatic control through the comparison of the setting and the actual value |
Equipment:
Aluminium housing powder coated, Handles, filter control via manometer, 2 guide- and 2 fixed castors, (only Compact 1800), starting current limit (only Compact 1800)